| Main model |
DH-004 |
DH-M005 |
DH-M008 |
DH-M012 |
DH-M018 |
DH-M030 |
DH-U008 |
DH-U012 |
DH-U018 |
DH-U030 |
| Type |
Shielded |
Non-shielded |
| Detecting distance |
1.2mm±10% |
2mm±10% |
4mm±10% |
8mm±10% |
15mm±10% |
4mm±10% |
8mm±10% |
16mm±10% |
30mm±10% |
| Setting distance |
0~0.84mm |
0~1.6mm |
0~3.2mm |
0~6.4mm |
0~12mm |
0~3.2mm |
0~6.4mm |
0~12.8mm |
0~24mm |
| Standard target |
5×5×1(mm) |
8×8×1(mm) |
12×12×1(mm) |
24×24×1(mm) |
45×45×1(mm) |
12×12×1(mm) |
24×24×1(mm) |
48×48×1(mm) |
90×90×1(mm) |
| Response frequency |
2KHz |
1.5KHz |
1KHz |
0.5KHz |
0.25KHz |
1KHz |
0.8KHz |
0.4KHz |
0.1KHz |
| Hysteresis |
1%~10% of detecting distance |
1%~15% of detecting distance |
1%~15% of detecting distance |
| Repeat precision |
Less than 3% of detecting distance |
Less than 5% of detecting distance |
Less than 5% of detecting distance |
| Power voltage |
12~24VDC |
10~30VDC |
10~30VDC |
| Current consumption |
<10mA |
<10mA |
<15mA |
<22mA |
<10mA |
<15mA |
<22mA |
| Output |
– |
NPN output
NPN open collector transistor
Load current: <100mA
Residual voltage: <2V (Load current 100mA and cable 2 m)
<200mA
2.5V or less(Load current 200mA and cable 2 m) |
NPN output
NPN open collector transistor
Load current: <100mA
Residual voltage: <2V (Load current 100mA and cable 2 m)
<200mA
2.5V or less(Load current 200mA and cable 2 m) |
| Indicator |
Yellow indicator (Lights up when output is ON) |
| Protection circuit |
Reverse polarity protection, Output short-circuit protection, Surge absorber |
| Ambient temperature |
Using:-25℃~+70℃; Storage:-25℃~+70℃ |
| Relative humidity |
Using:35~95%; Storage:35~95% |
| Withstand voltage |
500VAC, 50/60Hz 1min between the whole charging part and the enclosure |
1000VAC, 50/60Hz 1min between the whole charging part and the enclosure |
1000VAC,50/60Hz 1min between the whole charging part and the enclosure |
| Insulation resistance |
>20MΩ (DC500V) between the whole charging part and the enclosure |
>50MΩ (DC500V) between the whole charging part and the enclosure |
>50MΩ (DC500V) between the whole charging part and the enclosure |
| Vibration resistance |
10 to 55 Hz, double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions |
| Shock resistance |
500m/s² (Approx. 50G), 3 times in each of the X, Y, and Z directions |
| Protective structure |
IEC IP67 |
| Connection method |
Standard wire length 2m |
| Material |
Enclosure: Nickel-plated brass, Front end: PBT, Back end: PC |
| Weight |
– |
Approx. 50g |
Approx. 95g |
Approx. 115g |
Approx. 190g |
Approx. 50g |
Approx. 95g |
Approx. 115g |
Approx. 190g |