The ReeR EOS4 Master Slave Version is a configuration of Type 4 safety light curtains designed to extend protection coverage by connecting multiple light curtain pairs in a cascade system. In this setup, one unit acts as the Master, managing the safety outputs, while one or two additional Slave units are connected in series to expand the protective field. This architecture enables multi-side or large-area protection, ensuring that any interruption across the entire system triggers a single, unified safety stop signal.

This configuration is ideal for complex machinery layouts such as L-shaped guarding, multi-side access points or large automated systems, where a single light curtain is insufficient. The EOS4 Master Slave system maintains high safety performance with Type 4, SIL3, PL e Cat.4 certification, and supports integrated features such as External Device Monitoring (EDM) and selectable manual or automatic restart. It also allows connection distances of up to 50 m between units and up to 100 m total cable length, providing flexibility in installation across large machines.

For more info, download our full technical spec.

Specifications

Specification Detail
System Type Safety light curtain with Master Slave cascading
Safety Category Type 4, SIL3, SILCL3, PL e, Cat. 4
Configuration 1 Master unit + up to 2 Slave units (series connection)
Detection Type Finger, hand or body detection (model dependent)
Resolution 14 mm, 20 mm, 30 mm, 40 mm, 50 mm, 90 mm
Protected Height Expandable depending on number of connected units
Operating Range Up to 12 m (model dependent)
Response Time Depends on system configuration
Output Type 2 OSSD PNP safety outputs (Master unit)
Functions EDM, manual/automatic restart selectable
Connection M12 connectors, pre-wired cascading cables
Max Distance Between Units Up to 50 m
Total Cable Length Up to 100 m
Housing Dimensions 28 × 30 mm compact profile
Protection Rating IP65 to IP67
Operating Temperature -30 °C to +55 °C
Configuration Method Hardware based, no programming required

Get in Touch

Got a question about the product? Get in touch with us and we will guide you on every aspects of the product that you have questions about.

Related Products

Turck Banner – ED1G-L20MB-1N / ED1G-L21SMB-1N

Manual Enabling Control for Safe Machine Operation
Three Position Safety Switching Mechanism
Emergency Stop Activation by Release or Overtravel

Turck Banner – Safety Relays

Monitoring and Control of Safety Devices
Safe Switching of Machine Outputs
Implementation of Fixed Safety Logic Without Programming

Turck Banner – Safety I/O Modules

Distributed Safety Input and Output Control
Integration of Safety and Standard I/O Signals
Flexible Machine Level Installation and Expansion

Turck Banner – Programmable Safety Controller

Centralized Safety Logic Control
Monitoring Multiple Safety Devices
Flexible Programming and System Expansion

ReeR – Safety Controller MZero

Centralized Safety Logic Control
Monitoring and Processing of Safety Inputs
Flexible Configuration for Machine Safety Systems

ReeR – Safety Controller Interfaces

Safety Signal Interface and Relay Output Control
Monitoring and Control of Safety Devices
Restart Management and Safety Logic Handling