Transmitter
-
FlexTemp 2301
- Manufacturer: BAUMER
- 4…20 mA transmitter for Pt100 sensors
- 2-, 3- or 4-wire sensors
- Accuracy better than 0.25°C
- Sensor offset correction
- Automatic/confi gurable cable resistance compensation (2-wire)
- Sensor error detection
- 2-way confi guration (Windows)
- Confi gurable damping and status indication
- Engineering unit °C or °F
- PC datalogging
-
FlexTemp 2311
Category: Transmitter- 4…20 mA transmitter
- RTD, T/C, mV and R inputs
- Isolation voltage 2 kVac
- Configuration via FlexProgrammer
- Accuracy better than 0.1°C (Pt100)
- Configurable linearisation, damping and status indication
- Local, remote or fixed compensation for “cold junction” (CJC)
-
FlexTemp 2321
Category: Transmitter- 4…20 mA transmitter with HART® communication.
- RTD, T/C, mV and R inputs
- Isolation voltage 2 kVac
- Confi guration via FlexProgrammer or HART® confi gurator
- Accuracy < 0.1°C (Pt100)
- Confi gurable linearisation, damping and status indication
- Current-trim and sensor-trim
- Local, remote or fi xed compensation for “cold junction” (CJC)
-
FlexTop 2202
- Manufacturer: BAUMER
- 4…20 mA transmitter for Pt100 sensors
- 2-, 3- or 4-wire sensors
- Accuracy better than 0.25°C
- Sensor offset correction
- Automatic/configurable cable resistance compensation (2-wire)
- Sensor error detection
- 2-way configuration
- Configurable damping and status indication
- Engineering unit °C or °F
- PC datalogging
- Excellent temperature stability
- Ex ia IIC T5/T6, ATEX II 1G
-
FlexTop 2203
- Manufacturer: BAUMER
- 4…20 mA transmitter for T/C sensors
- Sensors type B, J, K, N and S
- Accuracy 4…5°C
- Sensor error detection
- Compensation for “cold junction” (CJC) Internal, external and fi xed.
- 2-way confi guration
- Confi gurable damping and status indication
- Engineering unit °C or °F
- PC datalogging
- Excellent temperature stability
- Ex ia IIC T5/T6, ATEX II 1G
-
FlexTop 2204
- Manufacturer: BAUMER
- 4…20 mA transmitter for Pt500 sensors and Resistance input
- 2-, 3- or 4-wire sensors
- Accuracy better than 0.25°C (Pt500)
- Sensor offset correction
- Automatic/configurable cable resistance compensation (2-wire)
- Sensor error detection
- 2-way configuration
- Configurable damping and status indication
- Engineering unit °C or °F
- PC datalogging
- Excellent temperature stability
- Ex ia IIC T5/T6, ATEX II 1G
- Ex nA II T5, ATEX II 3G
-
FlexTop 2211
- Manufacturer: BAUMER
- For RTD (resistance) or T/C (thermocouple)
- Input: RTD, T/C, mV and ohm
- Measuring range -270 … +2300 °C
- More accurate than 0.1 °C for Pt100
- ATEX explosion protection
- DIN form B housing installation
-
FlexTop 2211
- Manufacturer: BAUMER
- 4…20 mA transmitter
- RTD, T/C, mV and R inputs
- Isolation voltage 3.75 kVac
- Configuration via FlexProgrammer
- Accuracy better than 0.1°C (Pt100)
- Configurable linearisation, damping and status indication
- Local, remote or fixed compensation for “cold junction” (CJC)
- Ex approvals: Ex ia IIC T5/T6, ATEX II 1G, Ex nA II T5, ATEX II 3G
-
FlexTop 2212
- Manufacturer: BAUMER
- Programmable through integrated USB port
- Sensor calibration for either offset, slope or polynomial adjustment
- Accuracy better than 0.1°C for RTD elements
- Automatic cable compensation calibration (2-wire)
- Fast sampling time < 50 ms
- Isolation voltage 1.5 kVAC
- IECEx / ATEX pending
-
FlexTop 2221
- Manufacturer: BAUMER
- 4…20 mA transmitter with HART® communication.
- RTD, T/C, mV and R inputs
- Isolation voltage 3.75 kVac
- Configuration via FlexProgrammer or HART® configurator
- Accuracy < 0.1°C (Pt100)
- Configurable linearisation, damping and status indication
- Current-trim and sensor-trim
- Local, remote or fixed compensation for “cold junction” (CJC)
- Ex approvals: Ex ia IIC T5/T6, ATEX II 1G ,Ex nA II T5, ATEX II 3G
-
FlexTop 2222
- Manufacturer: BAUMER
- Universal transmitter with HART® communication
- Programmable through integrated USB port or HART® modem
- Sensor calibration for either offset, slope or polynomial adjustment
- Accuracy better than 0.1°C for RTD elements
- Automatic cable compensation calibration (2-wire)
- Fast sampling time < 50 ms
- Isolation voltage 1.5 kVAC
- IECEx / ATEX pending