  • FlexTemp 2301

    Category: Transmitter
    • 4…20 mA transmitter for Pt100 sensors
    • 2-, 3- or 4-wire sensors
    • Accuracy better than 0.25°C
    • Sensor offset correction
    • Automatic/confi gurable cable resistance compensation (2-wire)
    • Sensor error detection
    • 2-way confi guration (Windows)
    • Confi gurable damping and status indication
    • Engineering unit °C or °F
    • PC datalogging
  • FlexTemp 2311

    Category: Transmitter
    • 4…20 mA transmitter
    • RTD, T/C, mV and R inputs
    • Isolation voltage 2 kVac
    • Configuration via FlexProgrammer
    • Accuracy better than 0.1°C (Pt100)
    • Configurable linearisation, damping and status indication
    • Local, remote or fixed compensation for “cold junction” (CJC)
  • FlexTemp 2321

    Category: Transmitter
    • 4…20 mA transmitter with HART® communication.
    • RTD, T/C, mV and R inputs
    • Isolation voltage 2 kVac
    • Confi guration via FlexProgrammer or HART® confi gurator
    • Accuracy < 0.1°C (Pt100)
    • Confi gurable linearisation, damping and status indication
    • Current-trim and sensor-trim
    • Local, remote or fi xed compensation for “cold junction” (CJC)
  • FlexTop 2202

    Category: Transmitter
    • 4…20 mA transmitter for Pt100 sensors
    • 2-, 3- or 4-wire sensors
    • Accuracy better than 0.25°C
    • Sensor offset correction
    • Automatic/configurable cable resistance compensation (2-wire)
    • Sensor error detection
    • 2-way configuration
    • Configurable damping and status indication
    • Engineering unit °C or °F
    • PC datalogging
    • Excellent temperature stability
    • Ex ia IIC T5/T6, ATEX II 1G
  • FlexTop 2203

    Category: Transmitter
    • 4…20 mA transmitter for T/C sensors
    • Sensors type B, J, K, N and S
    • Accuracy 4…5°C
    • Sensor error detection
    • Compensation for “cold junction” (CJC) Internal, external and fi xed.
    • 2-way confi guration
    • Confi gurable damping and status indication
    • Engineering unit °C or °F
    • PC datalogging
    • Excellent temperature stability
    • Ex ia IIC T5/T6, ATEX II 1G
  • FlexTop 2204

    Category: Transmitter
    • 4…20 mA transmitter for Pt500 sensors and Resistance input
    • 2-, 3- or 4-wire sensors
    • Accuracy better than 0.25°C (Pt500)
    • Sensor offset correction
    • Automatic/configurable cable resistance compensation (2-wire)
    • Sensor error detection
    • 2-way configuration
    • Configurable damping and status indication
    • Engineering unit °C or °F
    • PC datalogging
    • Excellent temperature stability
    • Ex ia IIC T5/T6, ATEX II 1G
    • Ex nA II T5, ATEX II 3G
  • FlexTop 2211

    Category: Transmitter
    • For RTD (resistance) or T/C (thermocouple)
    • Input: RTD, T/C, mV and ohm
    • Measuring range -270 … +2300 °C
    • More accurate than 0.1 °C for Pt100
    • ATEX explosion protection
    • DIN form B housing installation
  • FlexTop 2211

    Category: Transmitter
    • 4…20 mA transmitter
    • RTD, T/C, mV and R inputs
    • Isolation voltage 3.75 kVac
    • Configuration via FlexProgrammer
    • Accuracy better than 0.1°C (Pt100)
    • Configurable linearisation, damping and status indication
    • Local, remote or fixed compensation for “cold junction” (CJC)
    • Ex approvals: Ex ia IIC T5/T6, ATEX II 1G, Ex nA II T5, ATEX II 3G
  • FlexTop 2212

    Category: Transmitter
    • Programmable through integrated USB port
    • Sensor calibration for either offset, slope or polynomial adjustment
    • Accuracy better than 0.1°C for RTD elements
    • Automatic cable compensation calibration (2-wire)
    • Fast sampling time < 50 ms
    • Isolation voltage 1.5 kVAC
    • IECEx / ATEX pending
  • FlexTop 2221

    Category: Transmitter
    • 4…20 mA transmitter with HART® communication.
    • RTD, T/C, mV and R inputs
    • Isolation voltage 3.75 kVac
    • Configuration via FlexProgrammer or HART® configurator
    • Accuracy < 0.1°C (Pt100)
    • Configurable linearisation, damping and status indication
    • Current-trim and sensor-trim
    • Local, remote or fixed compensation for “cold junction” (CJC)
    • Ex approvals: Ex ia IIC T5/T6, ATEX II 1G ,Ex nA II T5, ATEX II 3G
  • FlexTop 2222

    Category: Transmitter
    • Universal transmitter with HART® communication
    • Programmable through integrated USB port or HART® modem
    • Sensor calibration for either offset, slope or polynomial adjustment
    • Accuracy better than 0.1°C for RTD elements
    • Automatic cable compensation calibration (2-wire)
    • Fast sampling time < 50 ms
    • Isolation voltage 1.5 kVAC