Baumer Process Sensor

  • AFI4 HART

    Category: Conductivity Measurement
    • All-in-One conductivity sensor
    • All wetted parts in PEEK
    • Compact, food-safe, hygienic design
    • 3-A sanitary standards and FDA-compliant, EHEDG-certified
    • HART® communication protocol
  • AFI4 IO

    Category: Conductivity Measurement
    • All-in-One conductivity sensor
    • All wetted parts in PEEK
    • Compact, food-safe, hygienic design
    • 3-A sanitary standards and FDA-compliant, EHEDG-certified
    • IO-Link communication interface
  • AFI4 Normal

    Category: Conductivity Measurement
    • All-in-One conductivity sensor
    • All wetted parts in PEEK
    • Compact, food-safe, hygienic design
    • 3-A sanitary standards and FDA-compliant, EHEDG-certified
  • AFI5 HART

    Category: Conductivity Measurement
    • Separated sensor
    • Ideal for cramped spaces and strong vibrations
    • All wetted parts in PEEK
    • Compact, food-safe, hygienic design
    • 3-A sanitary standards, FDA-compliant, EHEDG-certified
    • HART® communication protocol
  • AFI5 IO

    Category: Conductivity Measurement
    • Separated sensor
    • Ideal for cramped spaces and strong vibrations
    • All wetted parts in PEEK
    • Compact, food-safe, hygienic design
    • 3-A sanitary standards, FDA-compliant, EHEDG-certified
    • IO-Link communication interface
  • AFI5 Normal

    Category: Conductivity Measurement
    • Separated sensor
    • Ideal for cramped spaces and strong vibrations
    • All wetted parts in PEEK
    • Compact, food-safe, hygienic design
    • 3-A sanitary standards, FDA-compliant, EHEDG-certified
  • CFAK 30P1200

    Category:
    • 30 mm
    • PNP make function (NO)
    • potentiometer, 18 turn
    • cable, 2 m
    • -25 … 75 °C
    • IP 67/65 (sensing face/sensor)
  • CFDK 25G1125/LN6

    Category:
    • 15 mm
    • push-pull
    • no
    • cable PVC 3 x 0,14, 2 m
    • -25 … 75 °C/li>
    • IP 65
  • CleverLevel LBFS

    Category:
    • Reliable in diverse media
    • Wide variety of process connections
    • For hygienic and industrial applications
    • With marine, ATEX, WHG and cULus approval
    • Process temperatures up to 200 °C
  • CombiPress PFMH

    Category: Hydrostatic PressureHygienic
    • Flush membrane with 3-A sanitary standards (FDA-compliant) and EHEDG
    • Resistant to all common CIP cleaning media and SIP-capable (150 °C max, < 30 min)
    • Versions available for high media temperatures (200 °C)
    • Built in graphical display (CombiView DFON optional) and programmable by touch screen or with FlexProgrammer 9701
    • Optionally available with additional relays and 4 … 20 mA with HART
    • Available with optional ATEX approval (4 … 20 mA output signal)
  • CombiPress PFMN

    Category: Flush MembraneHydrostatic Pressure
    • Programmable by touch screen
    • Cavity-free process connection
    • Resistant to all conventional CIP cleaning media
    • Compact installation from G 1/2 A
    • Optionally available with relay outputs
    • Absolute pressure, relative pressure and vacuum measurement
    • Easy and full programmable with FlexProgrammer 9701
  • CombiTemp TCR6

    Category: Industrial
    • Sensor and connection in stainless steel, AISI 316L
    • DIN form B housing
    • Robust design
  • CombiView DFON

    Category: Interfaces
    • Graphical display with backlight
    • Showing errors and limits by steady or flashing colours
    • Fits Baumer CombiSeriesTM (Ø80 mm FlexHousing)
    • Hygienic design
    • Option: Two configurable relay outputs
    • Programmable by touch screen
    • Easy and fully programmable with FlexProgrammer 9701
    • ATEX
    • UL
  • CTX

    Category: Industrial
    • Relative pressure measurement from -1 to 200 bar
    • Robust ceramic measuring cell
    • Stainless steel housing
    • Compact design
    • Relative pressure and vacuum measurement
  • FFAK 16NTD1001/L

    Category:
    • liquid level sensor
    • pulsed infrared diode
    • NPN
    • no
    • cable 3 pin, 2 m
    • 65 °C
    • IP 67
  • FlexFlow PF20H

    Category: Flow Measurement
    • SIP- capable without restrictions up to 150 °C / 24h
    • Broad portfolio of process connections
    • Flow and temperature measurement in a single sensor
    • Compact and robust
    • Available with IO-Link interface
  • FlexFlow PF20S

    Category: Flow Measurement
    • Parallel measurement of flow and temperature
    • Flow measurement independent of the mounting position
    • Large measuring range up to 400 cm/s
    • Measurement at high media temperatures up to 125 °C
    • High pressure resistance up to 100 bar
    • One-piece, compact measuring probe
    • Calibrated linear analog outputs for flow and temperature
    • IO-Link interface combined with analogue or switching output (programmable)
  • FlexProgrammer 9701

    Category: Interfaces
    • Operated from a PC, supplied from the USB port
    • Remote operation, supplied from a battery
    • User-friendly software with help menus
    • Configures the following products: Pxxx-series,CPX-series,FlexView,FlexBar 3431,FlexBar HRT,FlexTop 2201,FlexTop 2202,FlexTop 2203,FlexTop 2204,FlexTop 2211,FlexTop 2221,FlexTemp 2301,FlexTemp 2311,FlexTemp 2321,Level Switch LFFS + LBFS,TE2 with integrated transmitter,Combi-Series
  • FlexTemp 2301

    Category: Transmitter
    • 4…20 mA transmitter for Pt100 sensors
    • 2-, 3- or 4-wire sensors
    • Accuracy better than 0.25°C
    • Sensor offset correction
    • Automatic/confi gurable cable resistance compensation (2-wire)
    • Sensor error detection
    • 2-way confi guration (Windows)
    • Confi gurable damping and status indication
    • Engineering unit °C or °F
    • PC datalogging
  • FlexTemp 2311

    Category: Transmitter
    • 4…20 mA transmitter
    • RTD, T/C, mV and R inputs
    • Isolation voltage 2 kVac
    • Configuration via FlexProgrammer
    • Accuracy better than 0.1°C (Pt100)
    • Configurable linearisation, damping and status indication
    • Local, remote or fixed compensation for “cold junction” (CJC)
  • FlexTemp 2321

    Category: Transmitter
    • 4…20 mA transmitter with HART® communication.
    • RTD, T/C, mV and R inputs
    • Isolation voltage 2 kVac
    • Confi guration via FlexProgrammer or HART® confi gurator
    • Accuracy < 0.1°C (Pt100)
    • Confi gurable linearisation, damping and status indication
    • Current-trim and sensor-trim
    • Local, remote or fi xed compensation for “cold junction” (CJC)
  • FlexTop 2202

    Category: Transmitter
    • 4…20 mA transmitter for Pt100 sensors
    • 2-, 3- or 4-wire sensors
    • Accuracy better than 0.25°C
    • Sensor offset correction
    • Automatic/configurable cable resistance compensation (2-wire)
    • Sensor error detection
    • 2-way configuration
    • Configurable damping and status indication
    • Engineering unit °C or °F
    • PC datalogging
    • Excellent temperature stability
    • Ex ia IIC T5/T6, ATEX II 1G
  • FlexTop 2203

    Category: Transmitter
    • 4…20 mA transmitter for T/C sensors
    • Sensors type B, J, K, N and S
    • Accuracy 4…5°C
    • Sensor error detection
    • Compensation for “cold junction” (CJC) Internal, external and fi xed.
    • 2-way confi guration
    • Confi gurable damping and status indication
    • Engineering unit °C or °F
    • PC datalogging
    • Excellent temperature stability
    • Ex ia IIC T5/T6, ATEX II 1G
  • FlexTop 2204

    Category: Transmitter
    • 4…20 mA transmitter for Pt500 sensors and Resistance input
    • 2-, 3- or 4-wire sensors
    • Accuracy better than 0.25°C (Pt500)
    • Sensor offset correction
    • Automatic/configurable cable resistance compensation (2-wire)
    • Sensor error detection
    • 2-way configuration
    • Configurable damping and status indication
    • Engineering unit °C or °F
    • PC datalogging
    • Excellent temperature stability
    • Ex ia IIC T5/T6, ATEX II 1G
    • Ex nA II T5, ATEX II 3G
  • FlexTop 2211

    Category: Transmitter
    • For RTD (resistance) or T/C (thermocouple)
    • Input: RTD, T/C, mV and ohm
    • Measuring range -270 … +2300 °C
    • More accurate than 0.1 °C for Pt100
    • ATEX explosion protection
    • DIN form B housing installation
  • FlexTop 2211

    Category: Transmitter
    • 4…20 mA transmitter
    • RTD, T/C, mV and R inputs
    • Isolation voltage 3.75 kVac
    • Configuration via FlexProgrammer
    • Accuracy better than 0.1°C (Pt100)
    • Configurable linearisation, damping and status indication
    • Local, remote or fixed compensation for “cold junction” (CJC)
    • Ex approvals: Ex ia IIC T5/T6, ATEX II 1G, Ex nA II T5, ATEX II 3G
  • FlexTop 2212

    Category: Transmitter
    • Programmable through integrated USB port
    • Sensor calibration for either offset, slope or polynomial adjustment
    • Accuracy better than 0.1°C for RTD elements
    • Automatic cable compensation calibration (2-wire)
    • Fast sampling time < 50 ms
    • Isolation voltage 1.5 kVAC
    • IECEx / ATEX pending
  • FlexTop 2221

    Category: Transmitter
    • 4…20 mA transmitter with HART® communication.
    • RTD, T/C, mV and R inputs
    • Isolation voltage 3.75 kVac
    • Configuration via FlexProgrammer or HART® configurator
    • Accuracy < 0.1°C (Pt100)
    • Configurable linearisation, damping and status indication
    • Current-trim and sensor-trim
    • Local, remote or fixed compensation for “cold junction” (CJC)
    • Ex approvals: Ex ia IIC T5/T6, ATEX II 1G ,Ex nA II T5, ATEX II 3G
  • FlexTop 2222

    Category: Transmitter
    • Universal transmitter with HART® communication
    • Programmable through integrated USB port or HART® modem
    • Sensor calibration for either offset, slope or polynomial adjustment
    • Accuracy better than 0.1°C for RTD elements
    • Automatic cable compensation calibration (2-wire)
    • Fast sampling time < 50 ms
    • Isolation voltage 1.5 kVAC
    • IECEx / ATEX pending
  • LBFH

    Category: CleverLevel Level Switches
    • Safe detection of liquids, bulk solids and powders 
    • Short immersion length 
    • Excellent cleanability 
    • Capable of differentiation between foam and liquid 
    • Insensitive to adherent or sticky media 
    • Status indication by bright, multicolor LED 
    • Compact stainless steel housing, protection up to IP69K 
    • Teach-in on site or remote by control wire 
    • Two switching outputs with dedicated switching windows 
    • IO-Link configuration and interface
  • LBFI

    Category: CleverLevel Level Switches
    • Compact and robust stainless steel housing
    • On-site setting with qTeach
    • Two adjustable switching outputs
    • Multicolor LED display of switching statuses
    • Interface IO-Link
  • Level Switch LFFS

    Category: CleverLevel Level Switches
    • Wetted parts in acid-proof, stainless steel and PEEK 
    • Compact, food compatible, hygienic design 
    • Hygienic connections conform to 3-A standards, FDA de- mands and EHEDG guidelines 
    • Precise switching point without calibration 
    • Process temperature -40…200 °C 
    • Measures media with DC-values >1.5 (DC = Dielectric Constant) Data sheet LFFS
    • Not influenced by foam 
    • LED switch indicator 
    • Maintenance free 
    • Suitable for media separation measurement 
    • Configurable by FlexProgrammer 9701 
    • ATEX approval for gas and dust 
    • WHG approval (leakage and overfill)
  • LSP

    Category: Floatless
    • Potentiometric Level Transmitter
    • Wetted parts in acid-proof, stainless steel and PEEK
    • Compact, food compatible, hygienic design
    • 3-A approved / FDA and EHEDG compliant
    • Defined empty registration
    • LED level monitor
    • Unaffected by strong adhesive media
    • Configurable measuring range
  • PBM4

    Category: Industrial
    • Standard use in hydraulics from 10 to 1000 bar
    • Robust stainless steel housing
    • Compact design
    • Fully welded, dry measuring cell
    • E1 approval for mobile hydraulics
    • Relative pressure measurement
    • CANopen as option
  • PBMH

    Category: Hydrostatic PressureHygienic
    • 3-A sanitary standards, FDA-compliant, EHEDG-certified
    • Resistant to all common CIP cleaning media and SIP-capable (150 °C max, < 30 min)
    • Versions available for high media temperatures (200 °C)
    • Surface roughness connection Ra ≤ 0.8 for highest hygienic requirements
    • Fully welded and compact design for washdowns without residuals
    • Excellent active temperature compensation for increased process stability
    • External programming of zero point and span with FlexProgrammer 9701
    • Absolute pressure, relative pressure and vacuum measurement
  • PBMH

    Category: Hydrostatic PressureHygienic
    • 3-A sanitary standards, FDA-compliant, EHEDG-certified
    • Resistant to all common CIP cleaning media and SIP-capable (150 °C max, < 30 min)
    • Versions available for high media temperatures (200 °C)
    • Surface roughness connection Ra ≤ 0.8 for highest hygienic requirements
    • Fully welded and compact design for washdowns without residuals
    • Excellent active temperature compensation for increased process stability
    • External programming of zero point and span with FlexProgrammer 9701
    • Absolute pressure, relative pressure and vacuum measurement
  • PBMH

    Category: Hydrostatic PressureHygienic
    • 3-A sanitary standards, FDA-compliant, EHEDG-certified
    • Resistant to all common CIP cleaning media and SIP-capable (150 °C max, < 30 min)
    • Versions available for high media temperatures (200 °C)
    • Surface roughness connection Ra ≤ 0.8 for highest hygienic requirements
    • Fully welded and compact design for washdowns without residuals
    • Excellent active temperature compensation for increased process stability
    • External programming of zero point and span with FlexProgrammer 9701
    • Absolute pressure, relative pressure and vacuum measurement
  • PBMH autoclavable

    Category: Hydrostatic PressureHygienic
    • Fully autoclavable pressure sensor for common sterilization processes
    • High temperature resistance for SIP and CIP processes
    • Surface roughness of process connection Ra ≤ 0.8 for highest hygienic requirements
    • Fully welded and compact design for washdowns without residuals
    • Excellent active temperature compensation for increased process stability
    • External programming of zero point and span with FlexProgrammer 9701
  • PBMN flush

    Category: Flush MembraneHydrostatic Pressure
    • Flush membrane
    • Fully welded version
    • Robust stainless steel housing
    • External programming of zero point and span with FlexProgrammer 9701
    • High overpressure resistance
    • Available with option al ATEX approval (4 … 20 mA output signal)
  • PBMN high pressure

    Category: Industrial
    • Precision measurement from 60 to 1600 bar
    • Excellent temperature stability
    • Robust stainless steel housing
    • Fully welded, dry measuring cell
    • ATEX approval
    • Relative pressure measurement
  • PBMN industrial Low Pressure

    Category: Industrial
    • Excellent accuracy and active temperature compensation for precise pressure measurements
    • Universal field of applications due to fully welded and robust stainless steel housing
    • External programming of zero point and span with FlexPro-grammer 9701
  • PBMR

    Category:
    • Excellent accuracy and long-term stability up to ≤ 0.1% FS
    • Active temperature compensation throughout the entire operating temperature range
    • Sensor element fully welded to stainless steel housing
    • Tested for railway applications according to EN 50155:2007
    • Vibr
  • PBSN

    Category: Industrial
    • Robust stainless housing for harsh environment conditions
    • Standard use from -1 to 400 bar
    • Robust ceramic measuring cell
    • Abrasive resistant due to ceramic measurement cell
    • Absolute pressure, relative pressure and vacuum measurement
  • PP20H

    Category: Hydrostatic PressureHygienic
    • All market typical hygienic connections available
    • Resistant to all common CIP cleaning media
    • Condensate-proof measuring cell
    • Optionally available with IO-Link (in parallel to 4 … 20 mA)
    • Space-savng installations from DN 25 on
    • Absolute pressure, relative pressure and vacuum measurement
  • PROFSI3

    Category: Interfaces
    • Switching repeater for CleverLevel Ex i installations
    • ATEX certified
    • Galvanically isolated, intrinsically safe field circuit
    • Accepts one PNP output from LFFS, LBFS, LBFH or LBFI
    • Relay output with changeover contact
    • LED activity indicator)
    • Fail safe switching logic
    • Wide supply voltage range (22 V DC … 253 V AC)
    • Plug-in screw terminals
  • SensControl

    Category: Portable IO-Link Master
    • On-site configuration and monitoring of IO-Link devices (sensors/actuators)
    • Communication via WLAN, Bluetooth LE and IO-Link
    • Power supply by integrated rechargeable battery
    • Increased mobility and easy to use via SensControl app
  • TED

    Category:
    • -1 … 0 bar up to 0 … 400 bar
    • Robust stainless steel housing for severe industrial environments
    • Abrasive and chemical resistant
    • Two threshold outputs (PNP transistors or galvanic isolation)
  • Temperature Sensor TE2

    Category: HygienicIndustrial
    • Compact and light weight
    • Available with 4…20 mA transmitter or Pt100 output
    • Available with hygienic as well as industrial process connections
    • Programmable by FlexProgrammer 9701
  • TER8

    Category: Hygienic

    Temperature sensor type TER8 comprises a series of basic elements which can be combined in various ways to a TER8 temperature sensor. The product offers great flexibility in respect to modification, service and maintenance. The sensor can be made to feature a RTD output signal or with a built in temperature transmitter with 4-20 mA output.

  • TFRH

    Category: Hygienic
    • Pt100 sensor element, 2- or 4-wire
    • Built in graphical display, CombiViewTM DFON optional
    • Head mounted 4…20 mA transmitter, FlexTop type 22xx
    • HART®
    • ATEX
    • 3-A, FDA
    • Programmable by touch screen
    • Easy and full programmable with FlexProgrammer 9701
  • TFRN

    Category: Industrial
    • Pt100 sensor element, 2- or 4-wire
    • HART®
    • Built in graphical display, CombiViewTM DFON optional
    • Head mounted 4…20 mA transmitter, FlexTop type 22xx
    • ATEX
    • Programmable by touch screen
    • Easy and full programmable with FlexProgrammer 9701
  • U500.DA0.2-IA1B.72F

    Category:
    • 70 … 1000 mm
    • current output
    • qTeach, line-Teach
    • connector M12 5 pin
    • -25 … 65 °C
    • IP 67
Automation
Mechanical
Scroll to Top
Open chat
Hello 👋
Can we help you?
× How can I help you?